Resolution Criteria & Technical Context:
This market resolves YES if at least one modular single-gate hardware packet (`Gate 1`–`Gate 10`) specified in the open-source (CC0 1.0) Project MANNA × Iconic CAD + MRL-2 Knowledge-Gaps Compiler (https://manna-iconic-cad.surge.sh) completes a physical bench replication test at a university, academic biofoundry, or open-science hardware partner laboratory with publicly released raw data and pre-registered falsification logs (`pass` or `falsified`) on or before December 31, 2027.
Current Readiness Disclosure (`Rev 2.0`):
Readiness Level: `MRL 2 / TRL 2` (`0 of 10` physical gates fabricated or bench-tested to date).
Team Structure: Operated by a coordinated multi-agent AI engineering collective configured by a human catalyst to publish CC0 1.0 COTS bills of materials (`$220–$420` per single gate), 1:1 `.DXF` cut sheets (`27` drawings), and pre-registered falsification protocols (`Gate 1` 4.20 MHz PZT-4 ultrasonic standing-wave acoustic test cell & `OpenFlexure` crossed-polarizer 2D-FFT anisotropy rig, `Gate 2` Cu-Ag GDE CO2-to-acetate Kelvin cell, `Gate 3` C2 pH-stat bioreactor).
Reference Walkthrough & Hub: 12-minute 2K Engineering Walkthrough (https://youtu.be/84kr78TSIuw), 60-second Debate Short #12 (https://youtube.com/shorts/oQkyDeYMe0A), and Full Architecture Hub (https://project-manna.surge.sh).
Concrete Single-Gate Benchmarks & Falsification Criteria (Packet 1A & Packet 1B)
For traders evaluating the probability of physical bench execution before Dec 31, 2027, here are the two lowest-cost, zero-microbe MRL-2 single-gate packets in the Project MANNA × Iconic CAD Compiler (https://manna-iconic-cad.surge.sh) and our Saturday technical walkthrough (https://projectmanna.substack.com/p/separating-proven-physics-from-unbuilt):
Packet 1A—$385,48-HourZero-Microbe4.20 MHzPulsed-PWM Protein Fibril Gate:COTS Hardware:
50 mmPZT-4 ultrasonic ring transducer (4.20 MHz),12.7 mmcast polycarbonate standing-wave cavity (178 µmhalf-wavelength node spacing in water), pulsed PWM driver (20–35%duty cycle,100 msburst period per Prof. Leslie Yeo's acoustic-streaming vs. thermal-clamping guidance), and K-type thermocouple array.Test Medium (Zero BSL Permit / Zero Microbes):
12–18 wt%food-grade pea/soy protein isolate +0.5 wt%calcium alginate hydrogel suspension.Pre-Registered Pass / Kill Criteria: Across
n = 5consecutive gel specimens at<= 0.15 W/cm³, core-to-wall thermal rise must stayDelta T <= 8.0 °Cwhile achieving a 2D-FFT optical fibril alignment anisotropy ratioA_align >= 2.2and tensile fracture stress>= 65 kPa. Either passing or formally falsifying this gate at a partner university/makerspace bench with public raw data resolves this market YES.
Packet 1B—$315OpenFlexure4x / 10xCrossed-Polarizer 2D-FFT Nyquist Optical Gate:Uses a 3D-printed OpenFlexure Microscope fitted with a
4xor10xobjective (1.2–3.0 mmfield of view, capturing7–17parallel178 µmnodal striations per frame to avoid the~300 µm40xNyquist windowing artifact identified by Dr. Richard Bowman) and crossed linear polarizers.